beauty for Infusion pump--1200

beauty for infusion pump 1200

Compatible with IV sets of any brand with high accuracy. Automatically calibration for IV sets of any brand. Three working modes: Drop counting control,Rate control and Time control mode. 8 Hours internal battery life in high capacity. Have a unique color LCD and an internal battery with a high capability. Switch between ml/h and drops/min freely. Three levels of alarm volume: high, medium and low. Three levels of occlusion pressure: high, medium and low. KVO functio When finish the total volume of an infusion,   the pump will alarm and enter KVO state

Controls Drop counting and adjusting the delivery rate automaticallyPump Type Peristaltic finger Applicable IV Sets Compatible with IV sets of any standard(including lucifugal IV sets)Accuracy ≤25drop/min: ±2%,  >25drop/min:±3% (With the drop counting control mode) ±5% (With the rate control mode after the correct calibration)Delivery Rate Range 1~400drop/min(1drop/min step) 1.0ml/h~1200ml/h (1.0ml/h~99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)Delivery Time Range 1min~1999min (1 min step)Volume Limit Range 0~9999ml (1 ml step)Total Volume Range 1~9999ml (1 ml step)

Rapid injection 600ml/h

KVO Rate When the delivery rate≤10ml/h, KVO is  1 ml/h. Ot herwise KVO is 3ml/h. Alarms Air-in-line, Infusion complete when limited volume has been set, Empty container, Occlusion, Door is open, waiting time Over, No drop been detected, Operational errors, Low battery, other device failures.Power Supply AC power supply: AC 100 to 240V±10%,50/60HzInternal LI Battery: 11.1V, 2000mAh. 8 Hours of continous operation on a new fully charged battery with the rate of 20 drops/min.Power Consumption ≤25VASafety level Class, Type CFDimensions 130mm(L)× 200mm(W) × 230mm(H)Net Weight Approximately. 2.5kgOperating Conditions: Ambient temperature: 5 to 40°C Relative humidity: 20 to 90%Storage Conditions Ambient temperature-10 to 55°C Relative humidity: 10 to 90%Accessories AC power line, Operational manual 

ControlsDrop counting and adjusting the delivery rate automaticallyPump Type Peristaltic fingerApplicable IV SetsCompatible with IV sets of any standard(including lucifugal IV sets)Accuracy≤25drop/min: ±2%,  >25drop/min:±3% (With the drop counting control mode) ±5% (With the rate control mode after the correct calibration)Delivery Rate Range 1~400drop/min(1drop/min step)1.0ml/h~1200ml/h (1.0ml/h~99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)Delivery Time Rang: 1min~1999min (1 min step)Volume Limit Range 0~9999ml (1 ml step)Total Volume Range 1~9999ml (1 ml step)

Rapid injection: 600ml/h

KVO RateWhen the delivery rate≤10ml/h, KVO is  1 ml/h. Ot herwise KVO is 3ml/h. AlarmsAir-in-line, Infusion complete when limited volume has been set, Empty container, Occlusion, Door is open, waiting time Over, No drop been detected, Operational errors, Low battery, other device failures.Power SupplyAC power supply: AC 100 to 240V±10%,50/60HzInternal LI Battery: 11.1V, 2000mAh. 8 Hours of continous operation on a new fully charged battery with the rate of 20 drops/min.Power Consumption ≤25VADimensions 130mm(L)× 200mm(W) × 230mm(H)Net Weight Approximately. 2.5kgOperating Conditions Ambient temperature: 5 to 40°C Relative humidity: 20 to 90%Storage Conditions Ambient temperature: -10 to 55°C Relative humidity: 10 to 90%Accessories AC power line, Operational manual